BPMHV - EUTECTRODE 680
- MSDS: BPMHV
- Manufacturer: EUTECTIC CORP
- Product Name: EUTECTRODE 680
- National Stock Number: 3439-00-903-9257
Product Identification
Product ID:EUTECTRODE 680
MSDS Date:05/01/1986
FSC:3439
NIIN:00-903-9257
MSDS Number: BPMHV
Responsible Party
FLUSHING, NY 11358-9981
US
Emergency Phone: 718-358-4000
Info Phone: 718-358-4000;312-932-1210
Cage: 72271
Contractor
Telephone: 704-527-9800/ 800-221-1433
Cage: 72271
Ingredients
IRON
CAS: 7439-89-6
RTECS: NO4565500
OSHA PEL 10 MG/M3
ACGIH TLV: 5 MG/M3
CHROMIUM (SARA III)
CAS: 7440-47-3
RTECS: GB4200000
OSHA PEL 1 MG/M3
ACGIH TLV: 0.5 MG/M3
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
NICKEL (SARA III)
CAS: 7440-02-0
RTECS: QR5950000
OSHA PEL 1 MG/M3
ACGIH TLV: 0.05 MG/M3
SODIUM SILICATE
CAS: 1344-09-8
CALCIUM CARBONATE
CAS: 1317-65-3
RTECS: EV9580000
OSHA PEL 15 MG/M3 TDUST;5RESP
ACGIH TLV: 10 MG/M3 TDUST
TITANIUM OXIDE; (TITANIUM DIOXIDE)
CAS: 13463-67-7
RTECS: XR2275000
OSHA PEL 15 MG/M3 TDUST
ACGIH TLV: 10 MG/M3 TDUST; 9293
FELDSPAR
CAS: 68476-25-5
FERRO CHROME; (FERRO CHROMIUM)
CAS: 11114-46-8
RTECS: LK0750000
OSHA PEL 0.5 MG/M3 (CR)
ACGIH TLV: 0.5 MG/M3 (CR)
POTASSIUM HYDROXIDE (SARA III)
CAS: 1310-58-3
RTECS: TT2100000
OSHA PEL 2 MG/M3, C
ACGIH TLV: 2 MG/M3, C
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
MANGANESE (SARA III)
CAS: 7439-96-5
RTECS: OO9275000
OSHA PEL (C) 5 MG/M3 DUST
ACGIH TLV: 5 MG/M3 DUST 9293
POTASSIUM TITANATE
CAS: 12030-97-6
FLUORSPAR
CAS: 14542-23-5
OSHA PEL 2.5 (F) MG/M3
ACGIH TLV: 2.5 (F) MG/M3
BE CONSIDERED CARCIN. ABSORP OF CHROMIUM (VI)
RTECS: 9999999ZZ
KIDNEYS/LIVER. GOOD PRACT REQS REDUCTION OF EMPLOYEE
RTECS: 9999999ZZ
OVEREXP TO NICKEL CMPDS MAY CAUSE LUNG
RTECS: 9999999ZZ
INDICATED HIGH INCIDENCE OF LUNG/NASAL CANCERS.
RTECS: 9999999ZZ
OSHA ALTHOUGH IARC STATES SPECIFIC NICKEL CMPDS
RTECS: 9999999ZZ
RECOM GEN LIMIT FOR WELDING FUME IS 5 MG/M3.SHORT
RTECS: 9999999ZZ
AS DIZZ/NAUS/IRRIT OF NOSE, THROAT/EYES. ARC RAYS
RTECS: 9999999ZZ
OVEREXPOSURE MAY LEAD TO SIDEROSIS AND MAY EFFECT
RTECS: 9999999ZZ
. PROVIDE SCREENS & FLASH GOG, IF NEC, TO SHIELD
RTECS: 9999999ZZ
TO SEE WELD ZONE. THEN GO TO NEXT LIGHTER SHADE
RTECS: 9999999ZZ
APRONS, HATS, SHOULDER PROT, AS WELL AS
RTECS: 9999999ZZ
ELECTRICAL PARTS AND INSULATE HIMSELF FROM WORK AND
RTECS: 9999999ZZ
SILICON, CHROMIUM, NICKEL, MOLYBDENUM,
RTECS: 9999999ZZ
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:(ACUTE) CHROMIUM: INHAL OF FUME
W/CHROMIUM CMPD CAN CAUSE IRRIT OF RESP SYS,DMG TO LUNGS & ASTHMA
LIKE SYMP. SWALLOWING CHROMIUM (VI) SALTS CAN CAUSE SEV INJ/DEATH.
DUSTS ON SKIN CAN FORM ULCERS.EYES MAY BE BURNED BY CHROMIUM (VI)
CMPDS. ALLERGIC RXNS LIKELY IN SOME PEOPLE FROM CHROMIUM CMPDS.
NICKEL: (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NICKEL:GROUP 2B (IARC), GROUP 2 (NTP).
Effects of Overexposure:HLTH HAZ:METALLIC TASTE, NAUS,TIGHTNESS IN
CHEST, FEVER, ALLERGIC RXNS FROM OVEREXP.ALLERGIC RXNS LIKELY IN
ABOUT 10% OF WORKERS. (CHRONIC) MANGANESE:LONG TERM OVEREXP TO
MANGANESE CMPDS MAY AFFECT CN S.SYMP INCL MUSCULAR WEAK, TREMORS
SIMILAR TO PARKINSONS'S DISEASE. BEHAVIORAL CHANGES & CHANGES IN
HANDWRITING (SUPDAT)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:REMOVE TO WELL-VENTILATED AREA. CALL FOR MEDICAL AID. EMPLOY
FIRST-AID TECHNIQUES RECOMMENDED BY AMERICAN RED CROSS. INHALATION:
REMOVE FROM EXPOSURE. SUPPORT BREATHING (GIVE ARTIFICIAL
RESPIRATION/OX YGEN) . INGESTION: CALL MD IMMEDIATELY . SKIN: FLUSH
WITH COPIOUS AMOUNTS OF WATER. CALL MD . EYE: FLUSH WITH WATER FOR
AT LEAST 15 MINUTES .
Fire Fighting
Flash Point:NONFLAMMABLE
Extinguishing Media:USE MEDIA SUITABLE FOR SURROUNDING FIRE CONDITIONS
.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT . REFER TO ANSI Z49.1 FOR FIRE PROTECTION
DURING USE OF WELDING AND ALLIED PROCEDURES.
Unusual Fire/Explosion Hazard:WELDING ARC AND SPARKS AND BRAZING FLAMES
CAN IGNITE COMBUSTIBLES AND FLAMMABLES.
Accidental Release
Spill Release Procedures:NOT APPLICABLE.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:NONE SPECIFIED BY MANUFACTURER.
Other Precautions:READ AND UNDERSTAND MANUFACTURER'S INSTRUCTIONS AND
PRECAUTIONARY LABEL ON PRODUCT. TRAIN WORKER TO KEEP HIS HEAD OUT
OF FUMES.
Exposure Controls
Respiratory Protection:USE NIOSH/MSHA APPROVED RESPIRABLE FUME
RESPIRATOR OR AIR SUPPLIED RESPIRATOR WHEN WORKING IN CONFINED
SPACE OR WHERE LOCAL EXHAUST OR VENTILATION DOES NOT KEEP EXPOSURE
BELOW RECOMMENDED EXPOSURE LIM IT.
Ventilation:USE ENOUGH GENERAL VENTILATION AND LOCAL EXHAUST AT
ARC/BOTH, TO KEEP FUMES/GASES FROM WORKER'S BRTHG ZONE/GEN AREA.
Protective Gloves:WELDER'S GLOVES.
Eye Protection:CHEM WORK GOG/FULL LGTH FACESHLD(ING 21)
Other Protective Equipment:WEAR HAND, HEAD & BODY PROT WHICH HELP PVNT
INJURY FROM RADIA, SPARKS/ELEC SHOCK. AT MIN, THIS INCL ARM PROT,
(ING 23)
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EFTS OF OVEREXP: MAY ALSO APPEAR. EMPLOYEES EXPOS TO MANGANESE CMPDS
SHOULD GET QUARTERLY MED EXAMINATIONS FOR EARLY DETECTION OF
MANGANESE POIS. CHROMIUM: STUDIES HAVE SHOWN THAT CHROMATE
PRODUCTION WORKERS EXPOS TO HEXAVALENT CHROMIUM CMPDS HAVE EXCESS
OF LUNG CANCERS. CHROMIUM (VI) CMPDS ARE REQD BY OSHA TO (ING 13)
Chemical Properties
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Stability
Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:CO/CO*2. OZONE/NITROGEN OXIDES MAY BE
FORMED BY RADIA FROM ARC. FLUORIDES, COMPLEX OXIDES OF IRON,
MANGANESE, (ING 25)
Disposal
Waste Disposal Methods:PREVENT WASTE FROM CONTAMINATING SURROUNDING
ENVIRONMENT. DISCARD ANY PRODUCT, RESIDUE, DISPOSABLE CONTAINER OR
LINER IN AN ENVIRONMENTALLY ACCEPTABLE MANNER, IN FULL COMPLIANCE
WITH FEDERAL, STATE AN D LOCAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.